300/500V Blasting Cable 2 core twisted&twin copper conductor
Conductor material: Stranded or Solid Bare Copper Conductor
Conductor type: Twin or Twist
Conductor Size: 0.5sqmm up to 1.5sqmm or as request
Insulated: PVC / Rubber
Temperature range: 70°C
Voltage: 300/500V
Cable Color: Yellow-green, red-black,black or as request.
Application
Blasting Cable is useful for power leads for explosive devices,Mining, Gold Mining,Blasting underground rocks.
SDY Shot-Firing Mining Cable with solid PVC insulated copper conductor
Test voltage: 2 kV, 5 min. 50 Hz
Operating temperature: – 15°C to 65°C
Conductor: copper, solid, conductor, diameter: 0,6 mm or 0,75 mm
Insulation: special PVC, oxygen index > 29
Insulation colour: red
Application
Shot-firing cable for shooting works, for connecting electric detonator system with shooting line in all mines, in which shooting is performed, also in methane-areas of all hazard classes, according to mining regulations.
NOTE: If a coil of the SDY cable is protected with film (for transport and storage), remove the film before first use in places without the presence of electric detonators.
PSY Shot-Firing Mining Cable with PVC insulated conductors
Test voltage: 3 kV, 5 min. 50 Hz
Operating temperature: – 15°C to 70°C
Conductor: copper, multi-stranded class 5 acc. PN-EN 60228
Insulation: special PVC.
Conductor marking: red, green
Outer sheath: special, non-flammable PVC, preventing flame propagation, oxygen index > 29
Sheath colour: yellow
Application
Cable used for shooting as a fixed or portable shooting line in all mines, in which shooting is performed, also in methane-areas of all hazard classes, according to mining regulations.
NOTE: If a coil of the PSY cable is protected with film (for transport and storage), remove the film before first use in places without the presence of electric detonators
YDYp Shot-Firing Mining Cable with solid PVC insulated and sheathed copper conductor
Test voltage: 3 kV, 5 min. 50 Hz
Operating temperature: – 15°C to 65°C
Conductors: copper, solid class 1 acc.PN-EN 60228
Insulation: special PVC
Conductor marking:
2 x 2,5mm2: blue and black
2 x 6mm2: green and red
Outer sheath: special, non-flammable PVC preventing flame propagation, oxygen index > 29
Sheath colour: red
Application
Cable used for shooting as a fixed or portable shooting line in all mines, in which shooting is performed, also in methane-areas of all hazard classes, according to mining regulations.
NOTE: If a coil of the YDYp cable is protected with film (for transport and storage), remove the film before first use in places without the presence of electric detonators.
300/500V blasting cable Technical Data
Model | Core diameter | Strand count | Core material |
2*0.45 | 0.45 | 2 | Copper |
2*0.52 | 0.52 | 2 | Copper |
2*0.6 | 0.6 | 2 | Copper |
2*0.25*7 | 0.25 | 2 | Copper |
1*0.5*7 | 0.5 | 1 | Galvanized iron wire |
SDY Shot-Firing Mining Cable Technical Data
Conductor diameter [mm] | Calculated OD [mm] | Calculated cable weight [kg/km] |
1×0,6 | 1,8 | 6 |
1×0,75 | 2,0 | 8 |
PSY Shot-Firing Mining Cable Technical Data
Conductors/ cross section [n x mm2] | Maximum cable outer dimensions [mm x mm] | Calculated cable weight [kg/km] |
2×1,5 | 9,5×6,5 | 78 |
YDYp Shot-Firing Mining Cable Technical Data
Conductors/ cross section [n x mm2] | Maximum cable outer dimensions [mm x mm] | Calculated cable weight [kg/km] |
2×2,5 | 6,7 x 10,4 | 102 |
2×6 | 7,9 x 12,8 | 186 |