header-logo

HUADONG CABLE GROUP

Professional Cables and Wires Manufacturer in China

Type 440 and Type 441 Flexible Rubber Trailing Mining Cables

Application

Repeated trailing and reeling for dynamic equipment. For power supply to machinery and equipment such as draglines, shovels and drills.

Type 440 Flexible Rubber Mining Cable With Three Pilot Core Interstitial

Voltage Rating: 1.1kV to 22kV
Conductor: Tinned annealed copper wires
Separator/Screen: semi-conductive tape+ thermosetting compound over conductors
Insulation: Ethylene propylene rubber type R-EP-90
Insulation Screen:
1.1kV: Synthetic tape
From 3.3kV: Semi-conductive thermosetting compound + tinned copper/polyamide braid
Cable Assembly: Three screened power and three pilot cores laid up with right hand direction on cradle separator
Sheath: Thermosetting compound HD-85-PCP – extra heavy duty, oil resistance and flame retardant
STANDARDS: AS/NZS 2802: 2000, AS/NZS 1125:2001, AS/NZS 2802:2003

Type 441 Flexible Semi-Conductive Screened Mining Cable

Voltage Rating: Type 441.1 – 1.1kV; Type 441.3 – 3.3kV; Type 441.6 – 6.6kV; Type 441.11 – 11kV; Type 441.22 – 22kV
Conductor: Tinned annealed copper wires
Separator/Screen: semi-conductive tape+ thermosetting compound over conductors
Insulation: Ethylene propylene rubber type R-EP-90 and XR-EP-90
Insulation Screen: 1.1kV: Synthetic tape; From 3.3kV: semi-conductive thermosetting compound
Cable Assembly: Three screened power and three earth cores laid up with right hand direction on cradle separator with central pilot core
Inner Sheath: Semi-conductive thermosetting compound
Armour: Polyamide yarns
Outer Sheath: HD-CSP (Heavy duty Chlorosulphonated Polyethylene) extrra heavy duty, oil resistant and flame retardant
STANDARDS: AS/NZS 2802: 2000, AS/NZS 1125:2001, AS/NZS 2802:2003

Type 440 Mining Cable Data table
NOMINAL CONDUCTOR AREA THICKNESS OF INSULATION NOMINAL WEIGHT
mm² mm² kg/100m
Type 440.1-Class 2
6 1.5 135
10 1.5 166
16 1.6 204
25 1.6 269
35 1.6 324
50 1.7 403
70 1.8 539
95 2 659
120 2.1 802
150 2.3 1018
185 2.5 1198
240 2.8 1549
Type 440.3 – Class 2
16 3 304
25 3 379
35 3 446
50 3 524
70 3 659
95 3 754
120 3 914
150 3 1119
185 3 1289
240 3 1559
Type 440.6 – Class 2
16 5 444
25 5 523
35 5 599
50 5 689
70 5 834
95 5 964
120 5 1119
150 5 1349
185 5 1529
Type 440.11 – Class 2
25 7.6 759
35 7.6 869
50 7.6 974
70 7.6 1139
95 7.6 1319
120 7.6 1489
150 7.6 1679
Type 440.22 – Class 2
35 10.5 1429
50 10.5 1549
Get a free quote by e-mail: sales@huadongcablegroup.com

Type 441 Mining Cable Data table
NO. CORES NOMINAL CONDUCTOR AREA NOMINAL WEIGHT
mm² kg/100m
Type 441.1-Class 2
3+3 6 111
3+3 10 136
3+3 16 176
3+3 25 231
3+3 35 274
3+3 50 349
3+3 70 481
3+3 95 579
3+3 120 724
3+3 150 881
3+3 185 1049
3+3 240 1329
3+3 300 1629
Type 441.3-Class 1
3+3 16 241
3+3 25 304
3+3 35 359
3+3 50 446
3+3 70 571
3+3 95 659
3+3 120 794
3+3 150 931
3+3 185 1080
3+3 240 1310
3+3 300 1570
Type 441.6-Class 1
3+3 16 241
3+3 25 304
3+3 35 359
3+3 50 446
3+3 70 571
3+3 95 659
3+3 120 794
3+3 150 931
3+3 185 1080
3+3 240 1310
3+3 300 1570
Type 441.11-Class 1
3+3 25 481
3+3 35 542
3+3 50 620
3+3 70 750
3+3 95 850
3+3 120 986
3+3 150 1129
3+3 185 1289
3+3 240 1539
Type 441.22-Class 1
3+3 35 733
3+3 50 820
3+3 70 960
3+3 95 1070
3+3 120 1220
3+3 150 1380
3+3 185 1545
Get a free quote by e-mail: sales@huadongcablegroup.com

HUADONG CABLE GROUP SINCE 1999

Professional Cables and Wires Manufacturer in China

We can design cables according to your requirement

huadong-factory-01
huadong-factory-02
huadong-factory-03
huadong-factory-04
huadong-factory-05
huadong-factory-06

Verified Manufacturer

huadong-standards huadong-certificates

    Please feel free to leave your requirement, We will reply you in 12 hours.

    Your Name

    Your Email *

    Your Phone Number

    Your Country

    Your Requirement *

    whatapp-icon
    email-icon
    Inquiry

      sales@huadongcablegroup.com

      Name

      Email *

      Phone

      Requirement *

      X