Application
For trailing applications, including reeling applications. For opencast mining machinery including medium sized draglines, section feeders, shovels and drills.
SANS Type 63 1.9/3.3 kV Cable
Voltage Rating Uo/U: 1.9/3.3 kV
Conductor: Class 5 flexible stranded tinned annealed Copper
Insulation: EPR thermosetting compound
Braid: Nylon /Tinned copper wires
Pilot Core
Lay: Three tinned copper/nylon braid screened power cores and one unscreened pilot core laid up in the right hand lay around rubber (RD1) filler centre
Inner Sheath: CR (Polychloroprene Rubber)
Reinforcement braid: Open nylon braid – minimum 16 strings
Outer Sheath: CR (Polychloroprene Rubber)
STANDARDS: SANS 1520-2, SANS 1411-1, SANS 1411-3
SANS Type 66 / 66-ECC 3.8/6.6 kV Cable
Voltage Rating Uo/U: 3.8/6.6 kV
Conductor: Class 5 flexible stranded tinned annealed Copper
Insulation: EPR thermosetting compound
Braid: Nylon /Tinned copper wires
Pilot Cores: Insulated with EPM (Ethylene Propylene Monomer)
Lay: Each power core individually screened with tinned copper/ textile braid, laid up three insulated pilot cores
ECC Variant: One pilot core replaced with tinned conductor
Inner Sheath: CR (Polychloroprene Rubber)
Reinforcement braid: Open nylon braid – minimum 16 strings
Outer Sheath: CR (Polychloroprene Rubber)
STANDARDS: SANS 1520-2, SANS 1411-1, SANS 1411-3
Related hot-selling cables
HUADONG CABLE GROUP SINCE 1999
Professional Cables and Wires Manufacturer in China
We can design cables according to your requirement