Voltage : 10-AXEKVCE: 6/10kV; 22-AXEKVCE: 12.7/22kV; 35-AXEKVCE: 20/35kV
1: Aluminium conductor
2: Inner semiconducting layer
3: XLPE insulation
4: Outer semiconducting layer
5: Semiconducting water-blocking tape
6: Cu wire sreen and Cu tape counterhelix
7: Water-blocking tape
8: Outer PE sheath
Application : Cables are destined for loose installation in the air on supporting structures, in ground, into building blocks and into pipes made of non-magnetic material. Installation must be done according to valid standards and rules for cable laying in the ordinary and damp environments.
Get Price
Voltage : 10-AVXEKVCVE: 6/10kV; 22-AVXEKVCVE: 12.7/22kV; 35-AVXEKVCVE: 20/35kV
1: Aluminium conductor
2: Water-blocking strand
3: Inner semiconducting layer
4: XLPE insulation
5: Outer semiconducting layer
6: Semiconducting water-blocking tape
7: Cu wire sreen and Cu tape counterhelix
8: Water-blocking tape
9: Al foil
10: Outer PE sheath
Application : Cables are destined for loose installation in the air on supporting structures, in ground, into building blocks and into pipes made of non-magnetic material. Installation must be done according to valid standards and rules for cable laying in the ordinary and damp environments- dripping water, water showered on crossways, water spouting in all directions, temporary flooding.
Get Price
Voltage : 10-AVXEKVCVEY: 6/10kV; 22-AVXEKVCVEY: 12.7/22kV; 35-AVXEKVCVEY: 20/35kV
1: Aluminium conductor
2: Water-blocking strand
3: Inner semiconducting layer
4: XLPE insulation
5: Outer semiconducting layer
6: Semiconducting water-blocking tape
7: Cu wire sreen and Cu tape counterhelix
8: Water-blocking tape
9: Al foil
10: Outer PE sheath
Application : Cables are destined for loose installation in the air on supporting structures, in ground, into building blocks and into pipes made of non-magnetic material. Installation must be done according to valid standards and rules for cable laying in the ordinary and damp environments- dripping water, water showered on crossways, water spouting in all directions, temporary flooding.
Get Price
10-AXEKVCE, 22-AXEKVCE, 35-AXEKVCE
10-AXEKVCE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
3.4
16.4
2.5
26
390
672
1×70/16
RM
9.8
3.4
17.9
2.5
27
405
756
1×95/16
RM
11.3
3.4
19.4
2.5
29
435
859
1×120/16
RM
12.8
3.4
20.9
2.5
30
450
959
1×150/25
RM
14.2
3.4
22.3
2.5
32
480
1145
1×185/25
RM
15.8
3.4
23.9
2.5
33
495
1281
1×240/25
RM
18.1
3.4
26.2
2.5
36
540
1487
1×300/25
RM
20.2
3.4
28.3
2.5
38
570
1714
1×400/35
RM
23.3
3.4
31.4
2.5
41
615
2151
1×500/35
RM
26.5
3.4
34.6
2.5
44
660
2523
1×630/35
RM
29.9
3.4
38
2.5
47
705
2972
22-AXEKVCE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
5.5
20.6
2.5
30
450
825
1×70/16
RM
9.8
5.5
22.1
2.5
31
465
918
1×95/16
RM
11.3
5.5
23.6
2.5
33
495
1032
1×120/16
RM
12.8
5.5
25.1
2.5
34
510
1137
1×150/25
RM
14.2
5.5
26.5
2.5
36
540
1330
1×185/25
RM
15.8
5.5
28.1
2.5
37
555
1486
1×240/25
RM
18.1
5.5
30.4
2.5
40
600
1705
1×300/25
RM
20.2
5.5
32.5
2.5
42
630
1931
1×400/35
RM
23.3
5.5
35.6
2.5
45
675
2397
1×500/35
RM
26.5
5.5
38.8
2.5
48
720
2801
1×630/35
RM
29.9
5.5
42.2
2.5
51
765
3259
35-AXEKVCE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
8
25.6
2.5
35
525
1043
1×70/16
RM
9.8
8
27.1
2.5
36
540
1150
1×95/16
RM
11.3
8
28.6
2.5
38
570
1276
1×120/16
RM
12.8
8
30.1
2.5
40
600
1390
1×150/25
RM
14.2
8
31.5
2.5
41
615
1599
1×185/25
RM
15.8
8
33.1
2.5
42
630
1759
1×240/25
RM
18.1
8
35.4
2.5
45
675
1994
1×300/25
RM
20.2
8
37.5
2.5
47
705
2245
1×400/35
RM
23.3
8
40.6
2.5
50
750
2739
1×500/35
RM
26.5
8
43.8
2.5
53
795
3152
1×630/35
RM
29.9
8
47.2
2.5
56
840
3634
Get a free quote by e-mail: sales@huadongcablegroup.com
Get Price
10-AVXEKVCVE, 22-AVXEKVCVE, 35-AVXEKVCVE
10-AVXEKVCVE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×35/16
RM
7.2
3.4
15.3
2.5
25
500
661
1×50/16
RM
8.3
3.4
16.4
2.5
26
520
727
1×70/16
RM
9.8
3.4
17.9
2.5
28
560
815
1×95/16
RM
11.3
3.4
19.4
2.5
29
580
921
1×120/16
RM
12.8
3.4
20.9
2.5
31
620
1022
1×150/25
RM
14.2
3.4
22.3
2.5
32
640
1210
1×185/25
RM
15.8
3.4
23.9
2.5
34
680
1353
1×240/25
RM
18.1
3.4
26.2
2.5
36
720
1565
1×300/25
RM
20.2
3.4
28.3
2.5
38
760
1796
1×400/35
RM
23.3
3.4
31.4
2.5
41
820
2239
1×500/35
RM
26.5
3.4
34.6
2.5
44
880
2618
1×630/35
RM
29.9
3.4
38
2.5
48
960
3074
22-AVXEKVCVE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
5.5
20.6
2.5
30
600
879
1×70/16
RM
9.8
5.5
22.1
2.5
32
640
986
1×95/16
RM
11.3
5.5
23.6
2.5
33
660
1106
1×120/16
RM
12.8
5.5
25.1
2.5
35
700
1214
1×150/25
RM
14.2
5.5
26.5
2.5
36
720
1407
1×185/25
RM
15.8
5.5
28.1
2.5
38
760
1568
1×240/25
RM
18.1
5.5
30.4
2.5
40
800
1793
1×300/25
RM
20.2
5.5
32.5
2.5
42
840
2020
1×400/35
RM
23.3
5.5
35.6
2.5
45
900
2493
1×500/35
RM
26.5
5.5
38.8
2.5
49
980
2903
1×630/35
RM
29.9
5.5
42.2
2.5
52
1040
3367
35-AVXEKVCVE
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
8
25.6
2.5
35
700
1117
1×70/16
RM
9.8
8
27.1
2.5
37
740
1230
1×95/16
RM
11.3
8
28.6
2.5
38
760
1358
1×120/16
RM
12.8
8
30.1
2.5
40
800
1485
1×150/25
RM
14.2
8
31.5
2.5
41
820
1686
1×185/25
RM
15.8
8
33.1
2.5
43
860
1851
1×240/25
RM
18.1
8
35.4
2.5
45
900
2092
1×300/25
RM
20.2
8
37.5
2.5
47
940
2347
1×400/35
RM
23.3
8
40.6
2.5
50
1000
2847
1×500/35
RM
26.5
8
43.8
2.5
54
1080
3266
1×630/35
RM
29.9
8
47.2
2.5
57
1140
3755
Get a free quote by e-mail: sales@huadongcablegroup.com
Get Price
10-AVXEKVCVEY, 22-AVXEKVCVEY, 35-AVXEKVCVEY
10-AVXEKVCVEY
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×35/16
RM
7.2
3.4
15.3
2.5/1.5
28
560
837
1×50/16
RM
8.3
3.4
16.4
2.5/1.5
29
580
911
1×70/16
RM
9.8
3.4
17.9
2.5/1.5
31
620
1005
1×95/16
RM
11.3
3.4
19.4
2.5/1.5
32
640
1126
1×120/16
RM
12.8
3.4
20.9
2.5/1.5
34
680
1239
1×150/25
RM
14.2
3.4
22.3
2.5/1.5
35
700
1438
1×185/25
RM
15.8
3.4
23.9
2.5/1.5
37
740
1588
1×240/25
RM
18.1
3.4
26.2
2.5/1.5
39
780
1813
1×300/25
RM
20.2
3.4
28.3
2.5/1.5
42
840
2062
1×400/35
RM
23.3
3.4
31.4
2.5/1.5
44
880
2526
1×500/35
RM
26.5
3.4
34.6
2.5/1.5
48
960
2927
1×630/35
RM
29.9
3.4
38
2.5/1.5
51
1020
3406
22-AVXEKVCVEY
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
5.5
20.6
2.5/1.5
34
510
1094
1×70/16
RM
9.8
5.5
22.1
2.5/1.5
35
525
1201
1×95/16
RM
11.3
5.5
23.6
2.5/1.5
37
555
1328
1×120/16
RM
12.8
5.5
25.1
2.5/1.5
38
570
1447
1×150/25
RM
14.2
5.5
26.5
2.5/1.5
40
600
1653
1×185/25
RM
15.8
5.5
28.1
2.5/1.5
41
615
1822
1×240/25
RM
18.1
5.5
30.4
2.5/1.5
43
645
2062
1×240/25
RM
18.1
5.5
30.4
2.5/1.5
43
645
2062
1×300/25
RM
20.2
5.5
32.5
2.5/1.5
46
690
2308
1×400/35
RM
23.3
5.5
35.6
2.5/1.5
49
735
2802
1×500/35
RM
26.5
5.5
38.8
2.5/1.5
52
780
3234
35-AVXEKVCVEY
No. of cores and crossection
Conductor shape
Conductor diameter
Nominal insulation thickness
Diameter over insulation approx.
Nominal sheath thickness
Outer diameter approx.
Bending radius
Cable mass approx.
(mm2)
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
1×50/16
RM
8.3
8
25.6
2.5/1.5
39
585
1362
1×70/16
RM
9.8
8
27.1
2.5/1.5
40
600
1486
1×95/16
RM
11.3
8
28.6
2.5/1.5
42
630
1607
1×120/16
RM
12.8
8
30.1
2.5/1.5
43
645
1735
1×150/25
RM
14.2
8
31.5
2.5/1.5
44
660
1957
1×185/25
RM
15.8
8
33.1
2.5/1.5
46
690
2131
1×240/25
RM
18.1
8
35.4
2.5/1.5
48
720
2390
1×300/25
RM
20.2
8
37.5
2.5/1.5
50
750
2675
1×400/35
RM
23.3
8
40.6
2.5/1.5
54
810
3196
1×500/35
RM
26.5
8
43.8
2.5/1.5
57
855
3638
1×630/35
RM
29.9
8
47.2
2.5/1.5
60
900
4150
Get a free quote by e-mail: sales@huadongcablegroup.com
Get Price
Why Choose Us
Please feel free to leave your requirement, We will reply you in 12 hours.