header-logo

HUADONG CABLE GROUP

Professional Cables and Wires Manufacturer in China

Flexible Reeling/ Festoon/ Basket and Chain Cables for Cranes and Material Handling Equipment

NSHTOEU / (N)TSCGEWOEU/ (N)TSKCGEWOEU / (N)TSFLCGEWOEU / NGFLGOEU / (N)GRDGCGOEU / (N)GRDGOEU / 3GSLTOE / D12YST11YU11Y

Description and Application

Crane cable is used to cover a range of specialist cables powering and controlling cranes, hoists, festoons, conveyors and gantries. Used across heavy industry including mining and marine, they must be robust and capable of handling both torsional and tensile stresses simultaneously.

(N)TSFLCGEWOEU MV Flat Reeling Cable

1.-Flat-MV-reeling-cable

  • Application: Flexible medium voltage reeling cable for high mechanical stresses. Mainly for mobile equipment, e.g. fast-moving container cranes, cranes, large mobile equipment and excavators.
  • Voltage: 1.8/3kV, 3. 6/6kV, 6/10kV, 8. 7/15kV, 12/ 20 kV
  • Cores: 3C (+ FO)+ concentric ground
  • Conductor: Copper tinned, finely stranded, class F
  • Insulation: EPR
  • Sheath: EPR
  • Anti-torsion braid: Reinforced braid made of polyester threads
  • Outer Sheath: PCP
  • Data transmission: A special cable design with fibre-optics can be customized

(N)TSCGEWOEU/ (N)TSKCGEWOEU MV Round Reeling Cable

2.-Round-MV-reeling-cable-fiber-optics

  • Application: For application under high mechanical stresses. Mainly for mobile equipment, e.g. fast-moving container cranes and large moving equipment.
  • Voltage: 3. 6/6kV, 6/10kV, 8. 7/15kV, 12/ 20 kV
  • Cores: 3C+3G or 3C+2G+FO (also + control or BUS)
  • Conductor: Plain copper, fine stranded class 5
  • Insulation: EPR
  • Electrical field control: Inner and outer layer of semi-conductive rubber compound
  • Optical Fiber: 12 fibers, 50/125µ or 62.5/125µ or E9/125µ, within protection jacket
  • Inner Sheath: rubber (5GM3)
  • Reinforcement: Polyester anti-torsion braid
  • Outer Sheath: PCP(5GM5)

NSHTOEU LV Reeling Cable

3.LV-Round-Festoon-Cable

  • Application: Flexible low voltage reeling cable for application under high and very high mechanical stresses.
  • Voltage: 0.6/1kV
  • Conductor: Tinned copper flexible class 5
  • Insulation: EPR(3GI3)
  • Core identification: Up to 5 cores, From 6 cores: black with white numbers
  • Core arrangement: Central filler, plastic or textile, if necessary covered with rubber.
  • Inner Sheath: EPR rubber (5GM3)
  • Reinforcement: Wide-meshed polyester braid, embedded in the sheath
  • Outer Sheath: PCP / PUR (5GM5)
  • Marking: NSHTOEU-J (number of cores) x (cross-section)

6/10kV (N)TSFLCGEWOEU Flat Reeling Cable Parameter
cores x cross section Conductor diameter max. mm Min.Height mm Max.Height mm Min.Width mm Max.Width mm Bending radius free moving min. mm Weight (ca.) kg/km Permissible tensile force max. N
3×25+3×25/3E 6.9 25 27.5 66.7 69.7 413 2860 1125
3×35+3×25/3E 8.3 25.5 28.5 68.2 72.2 428 3260 1575
4×35+4×25/4E 8.3 25.5 28.5 86.7 91.7 428 4110 2100
3×50+3×25/3E 9.8 28.1 31.1 74.6 78.6 467 4030 2250
3×70+3×35/3E 11.4 29.7 32.7 79.2 83.2 491 4850 3150
4×70+4×35/4E 11.4 29.5 32.5 100.9 105.9 488 6240 4200
3×95+3×50/3E 13.3 31.7 34.7 84.7 89.7 521 5920 4275
3×120+3×70/3E 15.1 35.1 38.1 92.9 97.9 572 7420 5400

Get a free quote by e-mail: sales@huadongcablegroup.com

8.7/15kV (N)TSKCGEWOEU Reeling Cable with Fiber Opitc Parameter
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius free moving min. mm Weight (ca.) kg/km Conductor resis- tance at 20°C max.
3×25 + 2×25/2 +1x(12G62,5) 6.2 42 45 450 2700 0.78
3×35 + 2×25/2 +1x(12G62,5) 7.7 45 49 490 2960 0.55
3×50 + 2×25/2 +1x(12G62,5) 9.3 50 54 540 3960 0.39
3×70 + 2×35/2 +1x(12G62,5) 11.5 53 57 570 4760 0.27
3×95 + 2×50/2 +1x(12G62,5) 12.8 58 62 620 5760 0.21
3×120 + 2×70/2 +1x(12G62,5) 14.9 64 68 680 7265 0.16
3×150 + 2×70/2 +1x(12G62,5) 16.5 68 72 720 8500 0.13
3×185 + 2×95/2 +1x(12G62,5) 18.5 72 77 770 9900 0.11

Get a free quote by e-mail: sales@huadongcablegroup.com

0.6/1kV NSHTOEU Round Reeling Cable Parmater
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius free moving min. mm Weight (ca.) kg/km Currentcarrying capacity (1)
NSHTOEU-J Control cables
7×1,5 1.5 16.2 17.5 105 380 23
12×1,5 1.5 20 21.4 128 550 23
18×1,5 1.5 22.4 23.8 143 730 23
24×1,5 1.5 25.4 27 162 950 23
30×1,5 1.5 27.8 29.4 176 1140 23
7×2,5 2 18.5 19.7 118 510 30
12×2,5 2 22.7 24 145 740 30
18×2,5 2 25.8 27.4 164 1020 30
24×2,5 2 30.1 32.1 193 1410 30
NSHTOEU-J power cables, three core design
3×50+3×25/3 9.6 41 45 270 2850 202
3×70+3×35/3 11.1 43 47 282 3860 250
3×95+3×50/3 12.6 48 52 312 4720 301
3×120+3×70/3 13.7 50.5 55.5 333 5820 352
3×150+3×70/3 16 57 62 372 6535 404
3×185+3×95/3 17.7 63 68 408 8890 461
3×240+3×95/3 20.2 71 76 456 12040 540

Get a free quote by e-mail: sales@huadongcablegroup.com

NGFLGOEU-J Flat LV Cable For Festoon Operation

4.LV-Flat-Festoon-Cable

  • Application: Flexible low voltage power and control cable, for use on festoon systems and for connecting moveable parts of machine tools, material handling equipment, etc.
  • Voltage: 300/500V(600V)
  • Cores: Power: 4C,5C,7C; Control: multicore
  • Conductor: Eletrolytic copper, not tinned – up25mm2 Class6; -above35mm class5
  • Insulation: EPR(3GI3)
  • Individual screen: Braid screen made of tinned copper wires
  • Reinforcement: Wide-meshed polyester braid, embedded in the sheath
  • Outer Sheath: CR (5GM5)

(N)GRDGCGOEU-J Round LV Cable For Festoon Operation

6.-Chian-LV-Round-Festoon-Cable

  • Application: For use on festoon systems, e.g. on gantry cranes, hall gantry cranes, rack material handling equipment, transportation systems or machine tools.
  • Voltage: 0.6/1kV
  • Core: Power: 3C+3G,4C with overall CU screen
  • Conductor: copper, class5
  • Insulation: EPR(3GI3)
  • Inner Sheath: EPR(Black)
  • Screen: Braid screen made of tinned copper wires
  • Outer Sheath: PCP (5GM3)

(N)GRDGOEU/   (N)GRDGCGOEU LV Cable For Energy Chains

6.-Chian-LV-Festoon-Cable

  • Application: For use on festoon systems, e.g. on gantry cranes, hall gantry cranes, rack material handling equipment, transportation systems or machine tools.
  • Voltage: 0.6/1kV
  • Cores: Power:1C,3C+3G,4C,5C; Control: multicore
  • Conductor: Bare electrolytic copper, finely stranded, class 5
  • Insulation: EPR(3GI3), Alternative for control cables: ETFE
  • Screen: Braid screen made of tinned copper wires
  • Inner Sheath: EPR(GM1B) Black
  • Outer Sheath: EVA

0.6/1kV NGFLGOEU Cable Parameter
Number of cores x cross section Conductor diameter max. mm Min.Height mm Max.Height mm Min.Width mm Max.Width mm Bending radius free moving min. mm Weight (ca.) kg/km Permissible tensile force max. N
NGFLGOEU-J control cables
10×1,5 1.5 6.2 6.7 35.5 37 20 440 225
12×1,5 1.5 6.3 6.8 42 43.5 20 530 270
24×1,5 1.5 11.5 12.3 51 53.2 62 1040 540
42×1,5 1.5 15.1 16.1 70.2 72.3 81 1920 945
4×2,5 2 6.8 7.3 18.5 19.5 22 260 150
5×2,5 2 6.6 7.4 22.9 24.6 22 320 188
7×2,5 2 6.8 7.4 31 32.8 22 440 263
10×2,5 2 7.4 8 43 45.3 24 660 375
12×2,5 2 7.4 8 50.6 53.5 24 780 450
NGFLGOEU-J power cables
4×16 5.6 12.1 12.9 36 37.5 65 1060 960
4×25 6.6 13.6 14.4 41.9 43.4 72 1500 1500
4×35 8.1 14.8 16.7 47 49.9 84 2040 2100
5×4 2.8 8.5 9 28.9 31.2 36 510 300
5×6 3.5 9.1 9.6 31.8 34.1 38 640 450
5×10 4.5 10.5 11.3 39.2 41.6 45 960 750
5×16 5.6 12.2 12.7 45.1 47.6 64 1360 1200

Get a free quote by e-mail: sales@huadongcablegroup.com

0.6/1kV (N)GRDGCGOEU- J Cable Parameter
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius min. mm Weight (ca.) kg/km Nom.operating capaci- tance µF/km Inductance nom. mH/ km Current carrying capacity for install.
(N)GRDGCGOEU- J screened power cables
4×2,5 2 13 15 75 340 0.17 0.58 32
4×4 2.5 14.8 17.8 89 480 0.18 0.55 43
4×6 3 16.2 19.2 96 640 0.19 0.53 56
4×10 4 19.6 22.6 113 890 0.23 0.51 78
3×16+3×2,5 5.7 22.4 25.4 127 1150 0.225 0.48 104
3×25+3×4 6.8 25.4 28.4 142 1590 0.275 0.45 138
3×35+3×6 8.1 29.3 32.3 162 2160 0.325 0.43 170
3×50+3×10 9.6 35.4 38.4 192 3060 0.4 0.41 212
3×70+3×10 11.5 40.8 43.8 219 3960 0.475 0.39 263
3×95+3×16 12.9 43.4 46.4 232 4840 0.6 0.375 316
3×120+3×16 14.6 47.8 50.8 254 5910 0.7 0.36 370

Get a free quote by e-mail: sales@huadongcablegroup.com

0.6/1kV (N)GRDGOEU/ (N)GRDGCGOEU Cable Parmater
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius min. mm Weight (ca.) kg/km Permissible tensile force max. N Conductor resis- tance at 20°C max.
(N)GRDGOEU-J multicore power cables
4×4 2.9 12.7 14.7 74 320 240 4.95
4×6 3.6 14.2 16.2 81 430 360 3.3
4×10 4.6 16.7 18.7 94 670 600 1.91
4×16 5.9 21.2 23.2 116 1020 960 1.21
4×25 7.2 26.5 29.5 148 1600 1500 0.78
3×35+3×16/3 8.1 26.4 29.4 147 1770 1570 0.55
3×50+3×25/3 10 31.5 34.5 173 2560 2250 0.39
3×70+3×35/3 11.9 37.6 40.6 203 3550 3150 0.27
(N)GRDGCGOEU- J multicore power cables, overall screened
4×2,5C 1.9 11.2 13.2 66 310 150 7.98
4x4C 2.9 15.2 17.2 86 490 240 4.95
4x6C 3.6 17 19 95 650 360 3.3
4x10C 4.6 19.2 21.2 106 870 600 1.91
3×16+3×2,5C 5.9 20.3 22.3 112 1050 720 1.21
3×25+3x4C 7.2 25.7 28.7 144 1610 1120 0.78
3×35+3x6C 8.1 28.4 31.4 157 2140 1570 0.55
3×50+3×25/3 10 34.9 37.9 190 3080 2250 0.39
3×70+3×35/3 11.8 39.8 42.8 214 4090 3150 0.27

Get a free quote by e-mail: sales@huadongcablegroup.com

3GSLTOE LV Spreader Cable For Basket Operation

7.-spreader-pendent-basket

  • Application: Feeder cable for load-lifting equipment, e.g. spreader with high mechanical stress in gravity-fed collector basket operation. Suitable for operation in cold environment.
  • Voltage: 0.6/1kV
  • Cores: Control: multicores
  • Conductor: Bare electrolytic copper, finely stranded, class 5
  • Insulation: EPR(3GI3), Alternative for control cables: ETFE
  • Individual Screen: Braid screen made of tinned copper wires
  • Core arrangement: Core assembly: cores laid-up into bundles;
  • Bundle assembly: bundles laid-up around the central support element.
  • Outer Sheath: PUR (Black)

(N)SHTOEU LV Spreader Cable for Vertical Reeling

8.spreader-vertical-reeling-cable

  • Application: Flexible low voltage reeling cable for application under extreme mechanical stresses, specially designed for vertical reeling operation (spreader reeling application).
  • Voltage: 0.6/1kV
  • Cores: Control: multicores
  • Conductor: Bare electrolytic copper, finely stranded, class 5
  • Insulation: ETFE
  • Individual Screen: Braid screen made of tinned copper wires
  • Support element: Central aramide support element to increase the loading capability.
  • Inner sheath: PCP rubber
  • Core arrangement: Laid-up in a maximum of 3 layers
  • Outer Sheath: PCP rubber

D12YST11YU11Y LV Cable PUR Sheathed For Vertical Reeling

  • Application: Flexible low voltage reeling cable for application under high mechanical stresses, specially designed for vertical reeling operation (spreader reeling application).
  • Voltage: 0.6/1kV
  • Cores: Control: multicores
  • Conductor: Plain copper, flexible class 5
  • Insulation: Halogen free compound, based on polyester
  • Inner Sheath: PUR-HF (Polyurethane Halogen Free Flame Retardant)
  • Torsion protection: Open braid, reinforced
  • Outer Sheath: PUR-HF (Polyurethane Halogen Free Flame Retardant)

0.6/1kV Basket Spreader Cable Parameter
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius free moving min. mm Weight(ca.) kg/km Conductor resis- tance at 20°C max.
3GSLTOE-J control cables
24×2,5 2 29.1 32.1 161 1780 7.98
30×2,5 2 31.1 34.1 171 2260 7.98
36×2,5 2 34.5 37.5 188 2780 7.98
42×2,5 2 36.8 39.8 199 3490 7.98
48×2,5 2 41.3 44.3 222 4040 7.98
24×3,5 2.4 32 35 175 2350 5.55
30×3,5 2.4 34.3 37.3 187 2970 5.55
36×3,5 2.4 37.9 40.9 205 3750 5.55
42×3,5 2.4 42.4 45.4 227 4510 5.55
3GSLTOE-J control cables with bus element
24×2,5+1x(2×1)C 2 31.1 34.1 171 2200 7.98
24×2,5+4x(2×1)C 2 41.2 44.2 221 3600 7.98
36×2,5+2x(2×1)C 2 41.3 44.3 222 3830 7.98
42×2,5+2x(2×1)C 2 43.5 46.5 233 3600 7.98

Get a free quote by e-mail: sales@huadongcablegroup.com

0.6/1kV Spreader Vertical Reeling Cable Parameter
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Outer diameter max. mm Bending radius free moving min. mm Weight (ca.) kg/km Permissible tensile force max. N
(N)SHTOEU-J control cables
12×2,5 2 22 25 125 870 2700
24×2,5 2 26.2 29.2 146 1300 3600
30×2,5 2 29.4 32.4 162 1630 4100
44×2,5 2 34.1 37.1 186 2200 5100
(N)SHTOEU-J control cables with fiber optical
22×2,5+4x(3G50) 2 28.2 31.2 156 1390 3450
22×2,5+2x(3G62,5) 2 26.2 29.2 146 1260 3450
24×2,5+6x(2G62,5) 2 29.4 32.4 162 1510 3600
28×2,5+2x(3G62,5) 2 29.4 32.4 162 1590 3900
28×2,5+2x(3G50) 2 29.4 32.4 162 1590 3900
36×2,5+8x(1G62,5) 2 34.1 37.1 186 2050 4500
38×2,5+6x(2G62,5) 2 34.1 37.1 186 2090 4650
41×2,5+3x(2G62,5) 2 34.1 37.1 186 2150 4875
41×2,5+3x(2G50) 2 34.1 37.1 186 2160 4875

Get a free quote by e-mail: sales@huadongcablegroup.com

D12YST11YU11Y LV Cable Parmater
Number of cores x cross section Conductor diameter max. mm Outer diameter min. mm Weight (approx.) kg/km
24×2,5 2 23.8 980
30×2,5 2 25.8 1290
36×2,5 2 30.2 1530
42×2,5 2 34.1 1940
44×2,5 2 36.1 2080
9x(5×2,5) 2 38.8 2150
8x(6×2,5) 2 42.7 2620
14x(4×2,5) 2 40 2410

Get a free quote by e-mail: sales@huadongcablegroup.com

HUADONG CABLE GROUP SINCE 1999

Professional Cables and Wires Manufacturer in China

We can design cables according to your requirement

huadong-factory-01
huadong-factory-02
huadong-factory-03
huadong-factory-04
huadong-factory-05
huadong-factory-06

Verified Manufacturer

huadong-standards huadong-certificates

    Please feel free to leave your requirement, We will reply you in 12 hours.

    Your Name

    Your Email *

    Your Phone Number

    Your Country

    Your Requirement *

    whatapp-icon
    email-icon
    Inquiry

      sales@huadongcablegroup.com

      Name

      Email *

      Phone

      Requirement *

      X