Professional control cable manufacturer from China, Meet your kinds of requirement of (2-30 core ) control Cable. With over 30 years production experience and 15 years export experience, factory price without any third party.
The welding cable size can be customized according to your requirement, On-time delivery.
Multi-Core Control Cables List
The size( 2-30 core) for control cables we can customize according to your requirement.
2 Core Control Cable
Conductor: Copper; Core: 2 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
3 Core Control Cable
Conductor: Copper; Core: 3 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
4 Core Control Cable
Conductor: Copper; Core: 4 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
5 Core Control Cable
Conductor: Copper; Core: 5 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
6 Core Control Cable
Conductor: Copper; Core: 6 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
7 Core Control Cable
Conductor: Copper; Core: 7 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
8 Core Control Cable
Conductor: Copper; Core: 8 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
16 Core Control Cable
Conductor: Copper; Core: 16 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
Multi Core Control Cable
Conductor: Copper; Core: 2-24 Core; Insulation: PVC; Inner sheath: PVC Black color;
Shield: Unshield or Annealed copper tape shield.
Get Price
Muilti-Core 0.6/1kv (CVV) Unshielded Control Cable
4 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm Ohm/km Ohm/km kg/km m
4 0.5 7/0.30 0.8 1.8 11 36 0.0162 130 500/D
0.75 7/0.37 0.8 1.8 11.5 24.5 0.0142 150 500/D
1 7/0.40 0.8 1.8 11.5 18.1 0.0135 160 500/D
1.5 7/0.50 0.8 1.8 12.5 12.1 0.0115 195 500/D
2.5 7/0.67 0.8 1.8 14 7.41 0.0093 265 500/D
4 7/0.85 1 1.8 16.5 4.61 0.0092 390 500/D
6 7/1.04 1 1.8 17 3.08 0.0078 510 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
5 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm Ohm/km Ohm/km kg/km m
5 0.5 7/0.30 0.8 1.8 11.5 36 0.0162 150 500/D
0.75 7/0.37 0.8 1.8 12.5 24.5 0.0142 175 500/D
1 7/0.40 0.8 1.8 12.5 18.1 0.0135 190 500/D
1.5 7/0.50 0.8 1.8 13.5 12.1 0.0115 230 500/D
2.5 7/0.67 0.8 1.8 15 7.41 0.0093 320 500/D
4 7/0.85 1 1.8 18 4.61 0.0092 470 500/D
6 7/1.04 1 1.8 19.5 3.08 0.0078 620 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
6 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm Ohm/km Ohm/km kg/km m
6 0.5 7/0.30 0.8 1.8 12.5 36 0.0162 165 500/D
0.75 7/0.37 0.8 1.8 13 24.5 0.0142 190 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 205 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 255 500/D
2.5 7/0.67 0.8 1.8 16 7.41 0.0093 355 500/D
4 7/0.85 1 1.8 19.5 4.61 0.0092 525 500/D
6 7/1.04 1 1.8 21 3.08 0.0078 690 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
7 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm Ohm/km Ohm/km kg/km m
7 0.5 7/0.30 0.8 1.8 12.5 36 0.0162 170 500/D
0.75 7/0.37 0.8 1.8 13 24.5 0.0142 200 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 215 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 270 500/D
2.5 7/0.67 0.8 1.8 16 7.41 0.0093 380 500/D
4 7/0.85 1 1.8 19.5 4.61 0.0092 570 500/D
6 7/1.04 1 1.8 21 3.08 0.0078 795 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
8 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm Ohm/km Ohm/km kg/km m
8 0.5 7/0.30 0.8 1.8 13.5 36 0.0162 195 500/D
0.75 7/0.37 0.8 1.8 14 24.5 0.0142 230 500/D
1 7/0.40 0.8 1.8 14.5 18.1 0.0135 250 500/D
1.5 7/0.50 0.8 1.8 15.5 12.1 0.0115 310 500/D
2.5 7/0.67 0.8 1.8 17.5 7.41 0.0093 440 500/D
4 7/0.85 1 1.8 21 4.61 0.0092 660 500/D
6 7/1.04 1 1.8 23 3.08 0.0078 875 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
The other size for 0.6/1KV CVV Control Cable we can produce according to your requirement.
Get Price
Multi-Core 0.6/1KV (CVV-S) Screened Control Cable
4 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness of inner sheath Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of outer sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm mm Ohm/km Ohm/km kg/km m
4 0.5 7/0.30 0.8 1 1.8 13.5 36 0.0162 220 500/D
0.75 7/0.37 0.8 1 1.8 14 24.5 0.0142 245 500/D
1 7/0.40 0.8 1 1.8 14.5 18.1 0.0135 260 500/D
1.5 7/0.50 0.8 1 1.8 15.5 12.1 0.0115 300 500/D
2.5 7/0.67 0.8 1 1.8 16.5 7.41 0.0093 385 500/D
4 7/0.85 1 1 1.8 19 4.61 0.0092 530 500/D
6 7/1.04 1 1 1.8 20.5 3.08 0.0078 660 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
5 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness of inner sheath Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of outer sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm mm Ohm/km Ohm/km kg/km m
5 0.5 7/0.30 0.8 1 1.8 14.5 36 0.0162 250 500/D
0.75 7/0.37 0.8 1 1.8 15 24.5 0.0142 280 500/D
1 7/0.40 0.8 1 1.8 15.5 18.1 0.0135 295 500/D
1.5 7/0.50 0.8 1 1.8 16.5 12.1 0.0115 345 500/D
2.5 7/0.67 0.8 1 1.8 18 7.41 0.0093 445 500/D
4 7/0.85 1 1 1.8 20.5 4.61 0.0092 620 500/D
6 7/1.04 1 1 1.8 22.5 3.08 0.0078 780 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
6 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness of inner sheath Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of outer sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm mm Ohm/km Ohm/km kg/km m
6 0.5 7/0.30 0.8 1 1.8 15.5 36 0.0162 270 500/D
0.75 7/0.37 0.8 1 1.8 16 24.5 0.0142 305 500/D
1 7/0.40 0.8 1 1.8 16.5 18.1 0.0135 320 500/D
1.5 7/0.50 0.8 1 1.8 17.5 12.1 0.0115 375 500/D
2.5 7/0.67 0.8 1 1.8 19 7.41 0.0093 290 500/D
4 7/0.85 1 1 1.8 22 4.61 0.0092 685 500/D
6 7/1.04 1 1 1.8 24 3.08 0.0078 865 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
7 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness of inner sheath Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of outer sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm mm Ohm/km Ohm/km kg/km m
7 0.5 7/0.30 0.8 1 1.8 15.5 36 0.0162 275 500/D
0.75 7/0.37 0.8 1 1.8 16 24.5 0.0142 315 500/D
1 7/0.40 0.8 1 1.8 16.5 18.1 0.0135 330 500/D
1.5 7/0.50 0.8 1 1.8 17.5 12.1 0.0115 395 500/D
2.5 7/0.67 0.8 1 1.8 19 7.41 0.0093 520 500/D
4 7/0.85 1 1 1.8 22 4.61 0.0092 730 500/D
6 7/1.04 1 1 1.8 24 3.08 0.0078 930 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
8 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of core Nominal cross-sectional area No.& dia. Thickness Thickness of inner sheath Thickness Overall diameter (Approx.) Maximum conductor resistance Minimum insulation resistance Cable Standard Length
of wires of insulation of outer sheath (at20C) (at70C) weight (Approx.)
mm2 No./mm mm mm mm mm Ohm/km Ohm/km kg/km m
8 0.5 7/0.30 0.8 1 1.8 16 36 0.0162 310 500/D
0.75 7/0.37 0.8 1 1.8 17 24.5 0.0142 350 500/D
1 7/0.40 0.8 1 1.8 17 18.1 0.0135 370 500/D
1.5 7/0.50 0.8 1 1.8 18.5 12.1 0.0115 445 500/D
2.5 7/0.67 0.8 1 1.8 20 7.41 0.0093 590 500/D
4 7/0.85 1 1 1.8 23.5 4.61 0.0092 835 500/D
6 7/1.04 1 1 1.8 25.5 3.08 0.0078 1070 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
The other size for 0.6/1KV CVV-S Control Cable we can produce according to your requirement.
Get Price
Multi-Core 0.6/1KV (CVV-SWA) Armoure Control Cable
4 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armour Thickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C) Cable weight (Approx.) Standard Length
mm2 No./mm mm mm mm mm mm Ohm/km Ohm/km kg/km m
4 0.5 7/0.30 0.8 1.2 0.8 1.8 16.5 36 0.0162 380 500/D
0.75 7/0.37 0.8 1.2 0.8 1.8 17 24.5 0.0142 410 500/D
1 7/0.40 0.8 1.2 0.8 1.8 17 18.1 0.0135 425 500/D
1.5 7/0.50 0.8 1.2 0.8 1.8 18 12.1 0.0115 480 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 20.5 7.41 0.0093 715 500/D
4 7/0.85 1 1.2 1.25 1.8 23 4.61 0.0092 915 500/D
6 7/1.04 1 1.2 1.25 1.8 24.5 3.08 0.0078 1075 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
5 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armour Thickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C) Cable weight (Approx.) Standard Length
mm2 No./mm mm mm mm mm mm Ohm/km Ohm/km kg/km m
5 0.5 7/0.30 0.8 1.2 0.8 1.8 17 36 0.0162 420 500/D
0.75 7/0.37 0.8 1.2 0.8 1.8 18 24.5 0.0142 455 500/D
1 7/0.40 0.8 1.2 1.25 1.8 19 18.1 0.0135 595 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 20 12.1 0.0115 665 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 21.5 7.41 0.0093 805 500/D
4 7/0.85 1 1.2 1.25 1.8 24.5 4.61 0.0092 1040 500/D
6 7/1.04 1 1.2 1.6 1.8 27 3.08 0.0078 1385 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
6 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armour Thickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C) Cable weight (Approx.) Standard Length
mm2 No./mm mm mm mm mm mm Ohm/km Ohm/km kg/km m
6 0.5 7/0.30 0.8 1.2 0.8 1.8 18 36 0.0162 450 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 19.5 24.5 0.0142 610 500/D
1 7/0.40 0.8 1.2 1.25 1.8 20 18.1 0.0135 635 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 21 12.1 0.0115 715 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 22.5 7.41 0.0093 870 500/D
4 7/0.85 1 1.2 1.6 1.8 26.5 4.61 0.0092 1270 500/D
6 7/1.04 1 1.2 1.6 1.8 28.5 3.08 0.0078 1515 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
7 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armour Thickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C) Cable weight (Approx.) Standard Length
mm2 No./mm mm mm mm mm mm Ohm/km Ohm/km kg/km m
7 0.5 7/0.30 0.8 1.2 0.8 1.8 18 36 0.0162 455 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 19.5 24.5 0.0142 620 500/D
1 7/0.40 0.8 1.2 1.25 1.8 20 18.1 0.0135 650 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 21 12.1 0.0115 730 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 22.5 7.41 0.0093 895 500/D
4 7/0.85 1 1.2 1.6 1.8 26.5 4.61 0.0092 1315 500/D
6 7/1.04 1 1.2 1.6 1.8 28.5 3.08 0.0078 1580 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price
8 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armour Thickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C) Cable weight (Approx.) Standard Length
mm2 No./mm mm mm mm mm mm Ohm/km Ohm/km kg/km m
8 0.5 7/0.30 0.8 1.2 1.25 1.8 20 36 0.0162 625 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 20.5 24.5 0.0142 680 500/D
1 7/0.40 0.8 1.2 1.25 1.8 21 18.1 0.0135 710 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 22 12.1 0.0115 810 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 24 7.41 0.0093 995 500/D
4 7/0.85 1 1.2 1.6 1.8 28 4.61 0.0092 1470 500/D
6 7/1.04 1 1.2 1.6 1.8 30 3.08 0.0078 1770 500/D
Get the quote by e-mail: sales@www.huadongcablegroup.com
Get Price ]
The other size for 0.6/1KV CVV-SWA Control Cable we can produce according to your requirement.
Get Price
Why Choose Us?
We have 4 cable workshops, everyone about 10000 square meters, 20 sets advanced cable produce equipment, 20 high technology engineers, 150 staffs, Every production process has been strictly checked by our professional technical engineers.
Starting custom your ideal size, the factory price will send you in 12 hours.
E-mail: sales@www.huadongcablegroup.com
Get Price ]
Package & Delivery: Power cable package by iron or wooden drum or according to client’s requriement.
Customer Case :Our cable products have been exported to more than 30 countries, such as: Russian, America, Yemen, South America, North America, Middle East, Africa, Asia,Oceania countries and etc.