Minning Cable—NTMCWOEU/ NTMCGCWOEU Flexible Medium-Voltage Single Core Cable
Application
These cables are used for short connections of mobile transformer substations to overhead lines, also fFor use in railway vehicles, switching stations and control panels. Installation in cable ducts, tubes and outside. Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture.
NTMCWOEU Mining Flexible Medium-Voltage Single Core Cable
Voltage: 3,6/6kV to 12/20kV Conductor : Flexible, tinned copper class 5 Inner Conductor Layer: Special conductive rubber Insulation: EPR Outer Conductor Layer:Special conductive rubber. Screen: Spiral of tinned copper wires. Outer Sheath: PCP type 5GM3. Color: Black or Red
NTMCGCWOEU Mining Flexible Medium-Voltage Single Core Cable
Voltage: 3,6/6kV to 12/20kV Conductor: finely stranded class 5 (EN 60228, DIN VDE 0295) tinned, electrolytic copper Insulation: EPR compound (DIN VDE 0207, Part 20) Electrical field control: inner and outer layers of semi-conductive rubber Screen: spinning of tinned copper wires with cross section 16 or 25mm2 Outer sheath: 5GM3 compound, (acc. to DIN VDE 0207, Part 21), colour: red
6/10 KV NTMCWOEU Cable Parameter List
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No.×mm²
mm
mm
mm
kg/km
1×16/16
3.4
2.2
22
760
1×25/16
3.4
2.2
23.5
910
1×35/16
3.4
2.2
24.5
1040
1×50/16
3.4
2.2
27
1260
1×70/16
3.4
2.5
28.5
1530
1×95/16
3.4
2.5
30.5
1770
1×120/16
3.4
2.5
33.5
2180
1×150/25
3.4
3
35
2550
1×185/25
3.4
3
37
2900
1×240/25
3.4
3.5
41
3590
1×300/25
3.4
3.5
43
4280
1×400/35
3.4
4
46
5120
1×500/35
3.4
4
49
5950
1×630/35
3.4
4
53.5
7860
12/20 KV NTMCWOEU Cable Parameter List
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No.×mm²
mm
mm
mm
kg/km
1×25/16
5.5
2.5
28
1180
1×35/16
5.5
2.5
29.5
1320
1×50/16
5.5
2.5
31.5
1560
1×70/16
5.5
3
34
1920
1×95/16
5.5
3
36
2190
1×120/16
5.5
3
38
2460
1×150/25
5.5
3.5
40
2990
1×185/25
5.5
3.5
42
3350
1×240/25
5.5
3.5
45
3990
1×300/25
5.5
3.5
48
4760
1×400/35
5.5
4
52
6100
1×500/35
5.5
4
56
7010
1×630/35
5.5
4
60
8180
6/10 KV NTMCGCWOEU Cable Parameter List
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No.×mm²
mm
mm
kg/km
1×16/16KON
20.4
22.4
644
1×25/16KON
22.2
24.2
791
1×35/16KON
23.4
25.4
1050
1×50/16KON
25.4
28.4
1153
1×70/16KON
27.3
30.3
1399
1×95/16KON
29.3
32.3
1910
1×120/16KON
32
35
2044
1×150/25KON
33.7
36.7
2364
1×185/25KON
35.1
38.1
2709
1×240/25KON
39.4
42.4
3446
12/20 KV NTMCGCWOEU Cable Parameter List
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No.×mm²
mm
mm
kg/km
1×16/16KON
26
29
971
1×25/16KON
27.2
30.2
1090
1×35/16KON
28.4
31.4
1236
1×50/16KON
31
34
1680
1×70/16KON
32.5
35.5
1776
1×95/16KON
34.5
37.5
2170
1×120/16KON
37.2
40.2
2481
1×150/25KON
38.9
41.9
3020
1×185/25KON
40.3
43.3
3182
1×240/25KON
43.6
46.6
3870
HUADONG CABLE GROUP SINCE 1999
Professional Cables and Wires Manufacturer in China
We can design cables according to your requirement
Verified Manufacturer
Inquiry
X
Cookie Consent
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Contains information related to marketing campaigns of the user. These are shared with Google AdWords / Google Ads when the Google Ads and Google Analytics accounts are linked together.
90 days
__utma
ID used to identify users and sessions
2 years after last activity
__utmt
Used to monitor number of Google Analytics server requests
10 minutes
__utmb
Used to distinguish new sessions and visits. This cookie is set when the GA.js javascript library is loaded and there is no existing __utmb cookie. The cookie is updated every time data is sent to the Google Analytics server.
30 minutes after last activity
__utmc
Used only with old Urchin versions of Google Analytics and not with GA.js. Was used to distinguish between new sessions and visits at the end of a session.
End of session (browser)
__utmz
Contains information about the traffic source or campaign that directed user to the website. The cookie is set when the GA.js javascript is loaded and updated when data is sent to the Google Anaytics server
6 months after last activity
__utmv
Contains custom information set by the web developer via the _setCustomVar method in Google Analytics. This cookie is updated every time new data is sent to the Google Analytics server.
2 years after last activity
__utmx
Used to determine whether a user is included in an A / B or Multivariate test.
18 months
_ga
ID used to identify users
2 years
_gali
Used by Google Analytics to determine which links on a page are being clicked
30 seconds
_ga_
ID used to identify users
2 years
_gid
ID used to identify users for 24 hours after last activity
24 hours
_gat
Used to monitor number of Google Analytics server requests when using Google Tag Manager