Category: MV Medium Voltage Cables Type: Flexible & Trailing Cables For Reeling Applications; Conductor – Conductor and earth conductor made of electrolytic copper tinned, very finely stranded, class FS (refer also to DIN VDE 0295); Insulation – Protolon HS high grade special compound based on high-quality EPR (at least 3GI3); improved mechanical and electrical characteristics (refer also to DIN VDE 0207, Part 20; Core Identification – Natural coloured insulation with black semi-conductive layer Protofirm Sandwich – double layer inner sheath. Compound based on EPR, quality at least 5GM3, served as water barrier, colour: red Anti-torsion Braid – reinforced braid made of polyester threads, in a vulcanized bond between the sheaths, resulting in high strength of the sheath Protofirm Sandwich – double layer outer sheath: A sheath system with a unique combination of flexibility and robustness has been achieved through the use of a new sandwich structure. Abrasion and tear-proof high grade rubber compounds based on PCP, quality at least 5GM5, colour: bright red/red.
Parameters
Rated voltage: 3.6/6 kV 6/ 10 kV 8. 7/ 15 kV 12/ 20 kV Max. permissible operating voltage AC :4.2/7.2 kV 6. 9/ 12 kV 10. 4/ 18 kV 13. 9/ 24 kV Max. permissible operating voltage DC:5.4/10.8 kV 9/ 18 kV 13. 5/ 27 kV 18/ 36 kV AC test voltage : 11 kV 17 kV 24 kV 29 kV EMC:This design exhibits an extremely low interference level as a result of use a symmetrical three- core design with very narrow manufacturing rates. Data transmission:Special design with fibre-optics for trouble free data transmission at high data rates. Current Carrying Capacity description:According to DIN VDE 0298, Part 4. Higher values are permissible in specific cases (please consult the manufacturer).
(N)TSKCGEWOEU Reeling Cable Application
Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high or extreme mechanical stresses, e.g. high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stresses. Mainly for mobile equipment, e.g. fast-moving container cranes and large moving equipment.
(N)TSKCGEWOEU Reeling Cable Rated voltage 3. 6/ 6 k V
Contains information related to marketing campaigns of the user. These are shared with Google AdWords / Google Ads when the Google Ads and Google Analytics accounts are linked together.
90 days
__utma
ID used to identify users and sessions
2 years after last activity
__utmt
Used to monitor number of Google Analytics server requests
10 minutes
__utmb
Used to distinguish new sessions and visits. This cookie is set when the GA.js javascript library is loaded and there is no existing __utmb cookie. The cookie is updated every time data is sent to the Google Analytics server.
30 minutes after last activity
__utmc
Used only with old Urchin versions of Google Analytics and not with GA.js. Was used to distinguish between new sessions and visits at the end of a session.
End of session (browser)
__utmz
Contains information about the traffic source or campaign that directed user to the website. The cookie is set when the GA.js javascript is loaded and updated when data is sent to the Google Anaytics server
6 months after last activity
__utmv
Contains custom information set by the web developer via the _setCustomVar method in Google Analytics. This cookie is updated every time new data is sent to the Google Analytics server.
2 years after last activity
__utmx
Used to determine whether a user is included in an A / B or Multivariate test.
18 months
_ga
ID used to identify users
2 years
_gali
Used by Google Analytics to determine which links on a page are being clicked
30 seconds
_ga_
ID used to identify users
2 years
_gid
ID used to identify users for 24 hours after last activity
24 hours
_gat
Used to monitor number of Google Analytics server requests when using Google Tag Manager