1. Conductor : Rigid electrolytic copper Class I to sections of 10 mm² and class II for greater according to EN 60228 and IEC 60228.
2.Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath according to HD 603-1
4. Nominal voltage : 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature : 90 ºC
2.Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath according to HD 603-1
4. Nominal voltage : 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature : 90 ºC
1. Conductor: Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228
2. Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath DMZ-E type according to UNE 21123 and ST8 according to IEC 60502-1
4. Nominal voltage: 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature: 90 ºC
2. Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath DMZ-E type according to UNE 21123 and ST8 according to IEC 60502-1
4. Nominal voltage: 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature: 90 ºC
1. Conductor: Rigid electrolytic copper Class I to sections of 10 mm² and class II for greater according to EN 60228 and IEC 60228.
2. Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath according to HD 603-1
4. Nominal voltage: 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature: 90 ºC
7. Other characteristics:
2. Insulation: Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheath: Thermoplastic polyolefin sheath according to HD 603-1
4. Nominal voltage: 0.6/1 kV
5. Test voltage: 3.500 V A.C.
6. Maximum temperature: 90 ºC
7. Other characteristics:
1. Conductor: Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.
2. Insulation: Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE-HD 603-1
3. Sheath: Thermoplastic polyolefin sheath according to UNE-HD 603-1 and ST8 according to IEC 60502-1
4. Maximum temperature : 90 ºC
5. Nominal voltage: 0,6/1 kV
2. Insulation: Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE-HD 603-1
3. Sheath: Thermoplastic polyolefin sheath according to UNE-HD 603-1 and ST8 according to IEC 60502-1
4. Maximum temperature : 90 ºC
5. Nominal voltage: 0,6/1 kV
Why Choose Us