Welding & Battery Cable Construction
Conductor : Flexible bare annealed copper wire or tinned copper wire
Insulation: PVC or Rubber Material or EPR
Sheath: Natural rubber, Horoprene rubber or other syntheitic rubber,PVC or or CSP.
No.Cross-section: 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120m2, 150mm2, 185mm2 ,240mm2.
AWG: 6awg, 4awg, 2awg, 1awg, 1/0awg, 2/0awg, 3/0awg, 4/0awg, 250awg, 350awg, 500awg.
Gauge: 0 gauge, 1 gauge, 2 gauge, 4 gauge, 6 gauge, 8 gauge.
Color: Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
Welding Cable Description:
YH: Natural rubber sheath for welding cable
YHF: Horoprene rubber or other syntheitic rubber sheath welding cable
Working Temperature ≤ 60o C
Standard: IEC60245,ASTM,VDE,DIN etc.according to the other standards required by the customer.
25mm-70mm Flexble Rubber insulated Power Welding Cabl Parameter:
Description Core Numbers Conductors Range
Natural rubber sheath for welding cable 1 10~240mm2
Horoprene rubber or other syntheitic sheath welding cable 1 10~240mm2
Welding Cable to ASTM Standard
(AWG) | Nominal stranding | Nominal overall diameter | Approx. net weight (LBS/1000ft) | Max. conductor resistance at 20℃(Ω/km) | ||
AWG | mm | inch | mm | |||
6 | 259/30 | 259/0.254 | 0.43 | 10.92 | 152 | 1.33 |
4 | 418/30 | 418/0.254 | 0.475 | 12.07 | 215 | 0.84 |
2 | 646/30 | 646/0.254 | 0.54 | 13.72 | 296 | 0.53 |
1 | 836/30 | 836/0.254 | 0.58 | 14.73 | 360 | 0.42 |
1/0 | 1032/30 | 1032/0.254 | 0.615 | 15.62 | 424 | 0.33 |
2/0 | 1290/30 | 1290/0.254 | 0.655 | 16.64 | 513 | 0.26 |
3/0 | 1672/30 | 1672/0.254 | 0.72 | 18.29 | 644 | 0.21 |
4/0 | 2066/30 | 2066/0.254 | 0.78 | 19.81 | 824 | 0.17 |
Standards:
ASTM B-172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors
IEC 60228 Conductors of insulated cables
IEC 60245 Rubber insulated cables – Rated voltages up to and including 450/750 V
IEC 60332 Tests on electric and optical fibre cables under fire conditions
BS EN 50525 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U)